15-545-Order Recorded 4/19/1972In the Matter )
of )
Installing a )
pipeline )
IN THE BOARD OF COUNTY COMMISSIONERS
OF THE STATE OF OREGON
FOR THE COUNTY OF DESCHUTES
O R D E R
VOL 15 FADE 545
A permit is granted by Deschutes County to Jess Orr
to install a pipeline on or across Deschutes County
right-of-way.. A detailed description and map of this operation must be provided
on the reverse side of this sheet. This permit is subject to the following gen-
eral specifications and is revocable at any time upon written notice by the
Deschutes County Board of Commissioners.
GENERAL SPECIFICATIONS FOR PARTICULAR INSTALLATIONS
parallel with the road shall be in the existing ditch line, or no le ree
(3) feet from the edge of the existing pavement edge. Ines must be
installed to a depth to be no less than eet and properly backfilled to
:shall
he original grade line a o obstructions to the drainage area. Permittee
be re or any or all damages to the existing pavement, and
PrC nr nthPr nhir�rtc nr arAac ,ithin thA rinl,i_nf_s av
Installing Pipe Line Transverse: All pipe line installations
laid transversely to the road bed or right-of-way shall be installed in the
following manner: All pavement cuts prior to the excavation shall be made with
a breaking hammer so as to insure neat finish cut lines. All pipe lines shall
be installed to a depth of no less than two (2) feet below the existing road-
side ditch elevation. In all cases where a water line is installed in a trans-
verse direction the water pipe must be installed within a larger pipe which size
shall be no less than six (6) inches in diameter. Backfilling and Paving: The
permittee shall be required to properly backfill the trench in -such-a manner as
to guarantee a well compacted, stabli-ized sub -base prior to paving. The pave-
ment must be replaced to its original line, crown, and grade with an asphalt
mixture to conform with the surrounding road bed. The area of installation
must be kept smooth for the travelingpublicat all times. The permittee will
be required at all times to take every precaution to protect the traveling
public. All signs and traffic controls shall be furnished by the permittee.
In regard to other utility installations, such as gas lines, telephone lines and
electric conduits, all the general specifications shall apply if they are to be
run under ground, with one exception: It would not be necessary to have these
lines within a larger pipe when crossing the right-of-way.
Dated this /% day of 192.
Rmende,d App
Charles L. Plummer,
DESCHUTES COUNTY ROADMASTER
PERMITTEE
1 �
VOL
15 PACE 546