Loading...
15-545-Order Recorded 4/19/1972In the Matter ) of ) Installing a ) pipeline ) IN THE BOARD OF COUNTY COMMISSIONERS OF THE STATE OF OREGON FOR THE COUNTY OF DESCHUTES O R D E R VOL 15 FADE 545 A permit is granted by Deschutes County to Jess Orr to install a pipeline on or across Deschutes County right-of-way.. A detailed description and map of this operation must be provided on the reverse side of this sheet. This permit is subject to the following gen- eral specifications and is revocable at any time upon written notice by the Deschutes County Board of Commissioners. GENERAL SPECIFICATIONS FOR PARTICULAR INSTALLATIONS parallel with the road shall be in the existing ditch line, or no le ree (3) feet from the edge of the existing pavement edge. Ines must be installed to a depth to be no less than eet and properly backfilled to :shall he original grade line a o obstructions to the drainage area. Permittee be re or any or all damages to the existing pavement, and PrC nr nthPr nhir�rtc nr arAac ,ithin thA rinl,i_nf_s av Installing Pipe Line Transverse: All pipe line installations laid transversely to the road bed or right-of-way shall be installed in the following manner: All pavement cuts prior to the excavation shall be made with a breaking hammer so as to insure neat finish cut lines. All pipe lines shall be installed to a depth of no less than two (2) feet below the existing road- side ditch elevation. In all cases where a water line is installed in a trans- verse direction the water pipe must be installed within a larger pipe which size shall be no less than six (6) inches in diameter. Backfilling and Paving: The permittee shall be required to properly backfill the trench in -such-a manner as to guarantee a well compacted, stabli-ized sub -base prior to paving. The pave- ment must be replaced to its original line, crown, and grade with an asphalt mixture to conform with the surrounding road bed. The area of installation must be kept smooth for the travelingpublicat all times. The permittee will be required at all times to take every precaution to protect the traveling public. All signs and traffic controls shall be furnished by the permittee. In regard to other utility installations, such as gas lines, telephone lines and electric conduits, all the general specifications shall apply if they are to be run under ground, with one exception: It would not be necessary to have these lines within a larger pipe when crossing the right-of-way. Dated this /% day of 192. Rmende,d App Charles L. Plummer, DESCHUTES COUNTY ROADMASTER PERMITTEE 1 � VOL 15 PACE 546