15-643-Order Recorded 5/25/19726k`, IN T; -i_ COUNTY COURT OF THE STATE OF OREGON
FOR THE COUNTY OF DESCHUTES VOL 15 PAGE 643
In the hatter )
)
r
OT 1.ristRl ii np• n ��'t cas u
0 R 0 E R
4 rot, eater :sire in 'Tolls )
^.cres %oad.
A permit is granted by Deschutes County to City of Bond
to install vmtor ,,'.-ne line on or across Deschutes County
right-of-way. A detailed description and map of this operation must be provided
on the reverse side of this sheet. This permit is subject to the following gen-
eral specifications and is revocable at any time upon written notice by the
Deschutes County Court.
GENERAL SPECIFICATIONS FOR PARTICULAR INSTALLATIONS
instaillne Pike Line Parallel: dater IAli pipe lines running
parallel with the road shall be in the existing ditch line, or no less Than three
(3) feet from the edge of the existing pavement edge. All pipe lines must be
installed to a depth to be no less than two (2) feet and properly backfilled to
the original grade line and with no obstructions to the drainage area. Permittee
shall be responsible for any or all damages to the existing pavement, and
shoulders or other objects or areas within the right-of-way.
installing Pipa Line Transverse: All pipe line instal-
iations laid transversely to the road 'bed or right-of-way shall be installed in
the foilowing manner: All pavement cuts prior to excavation shall bo mada with
a breaking hammer so as to insure neat finish cut lines. All pipe lines shall
be installed to a depth of no less than Two (2) feet below the existing road-
side ditch elevation. In aiI cases where a wager line is installed in a trans -
versa direction the realer pipe must be installed a47 In a larger pipe which size
shall be no less than six (6) incites in diameter. Backfilling and Paving: The
permittee shall be required to properly backfill the trench in such a tanner as
to guarantee a well compacted, stabilized sub -base prior to paving. The pave -
.an must be replaced to its original line, crown, and grade with an asphalt
mixture to conform with the surrounding road bed. The area of installation
rust be kept smooth for the traveling public at all times. The permittee will
be required at ail times to take every precaution to protect the traveling
public. All signs and traffic controls shall be furnished by the permittea.
In retard to other utility installations, such as gas lines, telephone lines and
electric conduits, all the general specifications shall apply if they are to be
run under ground, with one exception: It would not be necessary to have these
lines within a larger pipe when crossing the right-of-way.
Dated this day of
Recommended Approval,-
Approved County Court: Charles L. Plummer,
DESCHUTES COUNTY ROADMASTER
JURGE ,
T, OvIV;
l NER
COiti'a ; i S I OVER Pt,�; t TTEE
VOL 15 FACE 644
— NW \(1. C -CV-\ -v,. C R SFC. aq