15-59-Order Recorded 9/30/1971rr�
'~ n� IN THE BOARD OF COUNTY COMMISSIONERS
OF THE STATE OF OREGON
FOR THE COUNTY OF DESCHUTES
In the Matter )
of ) ORDER
Installing a )
pipeline )
v:,L 15 PAGE 59
A permit.is granted by Deschutes County to Cascade.Natural Gas
to install ai elite on or across Deschutes County
right-of-way. A Retailed description and map of this operation must be provided
on the reverse side of this sheet. '.This permit is subject to the following gen-
eral specifications and is revocable at any time upon written notice by the
Deschutes County Board of Commissioners.
GENERAL SPECIFICATIONS FOR PARTICULAR INSTALLATIONS
Installing Pipe Line Parallel: All pipe lines running
parallel with the road shall be in the existing ditch line, or no less than three
(3) feet from the edge of the existing pavement edge. All pipe lines must be
installed to a depth to be no less than two (2) feet and properly backfilled to
the original grade line and with no obstructions to the drainage area. Permittee
shall be responsible for any or all damages'to the existing pavement, and
shoulders or other objects or areas within the right-of-way.
laid transversely to the road bed or right-of-way shall be installed in the
following manner: All pavement cuts prior to the excavation shall be m vith
a breaking hammer so as to insure neat finish cut lines. All pi nes shall
be installed to a depth of no less than two (2) feet below,existing road-
side ditch elevation. In all cases where a water li installed in -a trans-
verse direction the water pipe must be installe thin a larger pipe which size
shall be no less than six (6) inches in eter. Backfilling and Paving: The
permittee shall be required to.pro y backfill the trench in such a manner as
to guarantee a well compacte a¢liized sub -base p.rior to paving. The pave-
ment must be replaced .us original line, crown, and grade with an asphalt
mixture to confo lith the surrounding road bed. The area of installation
must be ke mooth for the traveling public at all times. The permittee will
be r red at all times to take every precaution to protect the travel in g
In regard to other utility installations, such as gas lines, telephone lines and
electric conduits, all the general specifications shall apply if they are to be.
run under ground, with one exception: It would not be necessary to have these
lines within a larger pipe when crossing the right-of-way.
Dated this -30 day of 197/.
Re omiended App r al
Charles L. Plummer,
DESCH UTES COUNTY ROADMASTEP.
PERMITTEE, f4�La
Form No. 336 Rev 7/66
CASCADE NATURAL GAS CORPORATION
jcF �i !
DISTRIBUTION LINE REPORT
Item Quantity
No. Proposed "As Built"
Stock No.
Description
1.
PWX-350
2" X -TRU COAT PIPE
2.
EL -360
2" 900 Weld ell.
3.
NP -213
1" Save -A -Valve nipple
4.
SP -352
2" Weld line stopper fitting
5.
1 SP -354
2" Extension stopper fitting
6.
1 TE -351
2" x 2" x 2" Weld tee
VOL 15 PAT 60
E. R. No. City
State Grid No._
Ft. Blacktop Ft. Concrete,
Ft. Gravel,
Sod, Dirt
Initiated by Date
Sales Representative
Prepared by nate
Distribution Clerk
Approved by Date
Head Serviceman
Constructed by Date
7. I NONE 2" End plate I Test press
8. t
9.
10.
11.
12.
13.
14.
"As — Built" by
Distribution Clerk
Checked by
Const. proble
Diagram No
Posted
Grid ❑
Date by.
acing ❑ Overall
"AS - BUILT"