Loading...
15-98-Order Recorded 9/28/1971P? k IN THE BOARD OF COUNTY COMMISSIONERS OF THE STATE OF OREGON L1`+ FOR THE COUNTY OF DESCHUTES VOL 15 PAGE 98 In the Matter ) of ) 0 R D E R Installing a ) water pipe ) A permit is granted by Deschutes County to Terrebonne Water District to install a water line on or across Deschutes County right-of-way. A detailed description and map of this operation must be provided on the reverse side of this street. This permit is subject to the following gen- eral specifications and is revocable at any time upon :,ritten notice by the Deschutes County Board of Commissioners. GENERAL. SPECIFICATIONS FOR PARTICULAR INSTALLATIO^JS para l l e l with the road sha.l 1 he in the existing ditch line, or no le ree (3) feet from the edge of the existing pavement edge. ines must be installed to a depth to be no less than - _ eet and properly backfilled to the original grade line an o obstructions to the drainage area. Permittee shall be res or any or all damage,'to the existing pavement, and �other-aro-asQ12 Installing Pipe Line Transverse_ All pipe line installations laid transversely to the road bed or right-of-way shall he. installed in the following manner: All pavement cuts prior to the excavation shall be made with a breaking hammer so as to insure neat finish cut lines. All pipe lines shall be installed to a depth of no less than two (2) feet 1,elow the existing road- side ditch elevation. In all cases where a water line is installed in a trans- verse direction the v:at:er pipe must be - installed with n a larger pipe which size shall be no less than six (6) inches in diameter. Bacl:fillin and Paving: The permittee shall be required to properly backfill the trench in such a manner as to guarantee a well compacted, stajrliized sub -hale prior to paving. The pave- ment must be replaced to its original line, crown, and grade with an asphalt mixture to conform with the sur•round-ing road bed. The area of installation must be kept smooth for the traveling public at all times. The permittee will be required at all times to take every precaution to protect the traveling public. All signs and traffic controls shall be furnished by the permittee. In regard to other utility installations, such as gas lines, telephone lines and electric conduits, all the general specifications shall apply if they are to be. run under ground, vrith one exception: It would not be, necessary to have these lines within a larger pipr� when crossing the right-of-vray. Dated this-- 2 -9 --day of___ 197/ Anroved Board of(Comirrissio I RYAd Pecommended Approval Charles L. Plummer, D;_S�H L 00011 T Y ROP,DMA,STEP. CONii'iI ER i CO1'1h1I i PERPII'TTEE �/L F s T VOL 1.9 rAC-tlog,