15-101-Order Recorded 10/22/1971IN THE COUNTY COURT OF THE STATE OF OREGON
In the Matter )
)
Of installing a 12" water
FOR THE COUNTY OF DESCHUTES
pipe line parallel and
transverse to Nels AndereL
Road, a total distance of 135
O R D E R
feet. (SEE MAP REVERSE SIDE)
Y: PACE 101
A permit is granted by Deschutes County to City of Bend
to install a water pipe line on or across Deschutes County
right-of-way. A detailed description and map of this operation must be provided
on the reverse side of this sheet. This permit is subject to the following gen-
eral specifications and is revocable at any time upon written notice by the
Deschutes County Court.
GENERAL SPECIFICATIONS FOR PARTICULAR INSTALLATIONS
Installing Pipe Line Parallel: Water &g pipe lines running
parallel with the road shall be in the existing ditch line, or no less than three
(3) feet from the edge of the existing pavement edge. All pipe lines must be
Installed to a depth to be no less than two (2) feet and properly backfilled to
the original grade line and with no obstructions to the drainage area. Permittee
shall be responsible for any or all damages to the existing pavement, and
shoulders or other objects or areas within the right-of-way.
installing Pipe Line Transverse: Water ,ice pipe line Instal-
lations laid transversely to the road bed or right-of-way shall be installed in
the following manner: Ali pavement cuts prior to excavation shall be made with
a breaking hammer so as to insure neat finish cut lines. All pipe lines shall
be installed to a depth of no less than two (2) feet below the existing road-
side ditch elevation. In all cases where a water line is installed in a trans-
verse direction the water pipe must be installed within a larger pipe which size
shall be no less than six (6) inches in diameter. Backfillinq and Paving: The
permittee shall be required to properly backfill the trench in such a manner as
to guarantee a well compacted, stabilized sub -base prior to paving. The pave-
ment must be replaced to its original line, crown, and grade with an asphalt
mixture to conform with the surrounding road bed. The area of installation
must be kept smooth for the traveling public at all times. The permittee will
be required at all times to take every precaution to protect the traveling
public. All signs and traffic controls shall.be furnished by the permittee.
In regard to other utility installations, such as gas lines, telephone lines and
electric conduits, all the general specifications shall apply if they are to be
run under ground, with one exception: It would not be necessary to have these
lines within a larger pipe when crossing the right-of-way.
Dated
th i s�day of ✓ 1�.
R mme/nded pr a
GGA
Charles L. Plummer,
DESCHUTES COUNTY ROADMASTER
PERMITTEE
See attached sheet for Special Conditions
1).-ir1-off 43s�n'�Z
i
LN31N3S`d� hi -I-111(1 az
22 - io1
O
koa
�3 i9 Vl
7-3 Wq � NmobJ
SPECIAL CONDITIONS:
The City of Bend agrees to accept full legal and financial responsibility
to move proposed water pipe line and accessories if said water pipe line
and accessories should ever interfere with the pvvposed road improvements
for Nels Anderson Road, as plans show this day, October 20, 1971.