Loading...
15-107-Order Recorded 11/2/1971VOL 15 ?AGF 07 IN THE BOARD OF COUNTY COMMISSIONERS OF THE STATE OF OREGON FOR THE COUNTY OF'DESCHUTES In the Matter ) of ) ORDER Installation of a ) pipeline A permit.is granted by Deschutes County. to,, K FS.Builders to install a pipeline on or across Deschutes County right-of-way. A detailed "description and map of this operation must be provided on the.reverse side of this sheet. This permit is subject to the following gen- eral specifications and is revocable at any time upon written notice by the Deschutes County Board of Commissioners. GENEtRA,L SPECIFICATIONS?FOR PARTICULAR INSTALLATIONS parallel with the road shall be in the e>isting ditch line, or no ree (3) feet from the edge of the existing pavement ed ipe lines must be installed to a depth to be no less feet and properly backfilled to the original grade li no obstructions to the drainage area. Permittee shall i e for any or all damages' to the existing pavement, and Installing Pipe Line Transverse: All pipe line installations laid transversely to the road bed or right-of-way shall be installed in the following manner: All pavement cuts prior to the excavation shall be made with a breaking hammer so as to insure neat fiW sh,cut lines. All pipe lines shall be installed to a depth of no less than two (2) feet below the existingroad- side ditch elevation. In all cases where,a,i,later line is installed in -a trans- verse direction the water pipe must be installed within a larger pipe which size shall hp ro less than six (F.) inches in diamn+r v Ba,kf ill' .""1 D,.., i T -o -, Y Ca ...n ir.i u !" 1 UV 1 19: Ilii: permittee shall be required to -properly backfill the trench in such a manner as to guarantee a well compacted, stapliized sub -base prior to paving. The pave- ment must be replaced to its original line, croirn, and grade with an asphalt mixture to conform with the surrounding road bed. The area of installation must be kept smooth for the traveling public at all times. The permittee will be required at all times to take every precaution to protect the traveling public. All signs and traffic controls shall be furnished by the permittee. In regard to other utility installations, such as gas lines, telephone lines and electric conduits, all the general specifications shall apply if they are to be - run under ground, with one exception: It would not be necessary to have these lines within a larger pipe when crossing the right-of-way. Dated this c;� day of 19-7/ Reco mended Approval Approved Board of mmissione s: G Z' harles L. Plummer, DESCHUTES COUNTY ROADMASTEP, I R1 N _ P RMITTE I pov AS