Loading...
11-550-Order Recorded 2/29/19689VOL ?AGE 550 IN THE COUNTY COURT OF THE STATE OF OREGON FOR THE COUNTY OF DESCHUTES Tn the Matter ) of ) ORDER Power Cable Crossing ) A permit is granted by Deschutes. County to MIDSTATE ELECTRIC COOP, INC. to install an underground ca5le on or across Deschutes County right-of-way. A detailed description and map of this operation must be provided on the reverse side of this sheet. This permit is subject to the following gen- eral specifications and is revocable at any time upon written notice by the Deschutes County Court. GENERAL SPECIFICATIONS FOR PARTICULAR INSTALLATIONS Installing Me Line Parallel: Buried Electrical cable. All pipe lines running parallel with the road shall be in the existing ditch line, or no less than three (3) feet from the edge of the existing pavement edge. All pipe lines must be installed to a depth to be no less than two (2) feet and properly backfilled to the original grade line and with no obstructions to the drainage area. Permittee shall be responsible for any or all damages to the existing pavement, and shoulders or other objects or areas within the right-of-way. lations laid transversely to the road bed or right-of-way shall be in ed in the following manner: All pavement cuts prior to excavation sha e made with a breaking hammer so as to insure neat finish cut lines. ipe lines shall be installed to a depth of no less than two 42) feet the existing road- side ditch elevation. In all cases where a wate ne.- i6 installed in a trans- verse direction the water pipe must be Inst d within a larger pipe which size shall be no less than six (6) inches ameter. Backfilling and Paving: The permittee shall be required to p rly backfill the trench in such a manner as to guarantee a well compact , stabilized sub -base prior to paving. The pave- ment must be replaced, is original line, crown, and grade with an asphalt mixture to confo 'th the surrounding road bed. The area of installation must be k ooth for the traveling public at all times. The permittee will be re ed at all times to take every precaution to protect the traveling In regard to other utility installations, such as gas lines, telephone lines and electric conduits, all the general specifications shall apply if they are to be run under ground, with one exception: It would not be necessary to have these lines within a larger pipe when crossing the right-of-way. Dated this ..2 day of Rec ended Appova / Charles L. Plummer, DESCHUTES COUNTY ROADMASTER PERNI7TUI Cx C4, It PACE551 2: C.A JYPIC-AL SECTION DRAWFj of- PROPOSED 3� o),57RIBUTMA/ Po!,I,rP I NE A ND A 3 0 T. -r R 0 1) fi n C,4,8 L Z N D FS c r_'lou,,y7-y ROAD R l U h T OF WAY IN SEC T.20 -S - R/0 '1/ hl LrNUTIj c)F P, H L. bY E 333