11-550-Order Recorded 2/29/19689VOL ?AGE 550
IN THE COUNTY COURT OF THE STATE OF OREGON
FOR THE COUNTY OF DESCHUTES
Tn the Matter )
of ) ORDER
Power Cable Crossing )
A permit is granted by Deschutes. County to MIDSTATE ELECTRIC COOP, INC.
to install an underground ca5le on or across Deschutes County
right-of-way. A detailed description and map of this operation must be provided
on the reverse side of this sheet. This permit is subject to the following gen-
eral specifications and is revocable at any time upon written notice by the
Deschutes County Court.
GENERAL SPECIFICATIONS FOR PARTICULAR INSTALLATIONS
Installing Me Line Parallel: Buried Electrical cable. All pipe lines running
parallel with the road shall be in the existing ditch line, or no less than three
(3) feet from the edge of the existing pavement edge. All pipe lines must be
installed to a depth to be no less than two (2) feet and properly backfilled to
the original grade line and with no obstructions to the drainage area. Permittee
shall be responsible for any or all damages to the existing pavement, and
shoulders or other objects or areas within the right-of-way.
lations laid transversely to the road bed or right-of-way shall be in ed in
the following manner: All pavement cuts prior to excavation sha e made with
a breaking hammer so as to insure neat finish cut lines. ipe lines shall
be installed to a depth of no less than two 42) feet the existing road-
side ditch elevation. In all cases where a wate ne.- i6 installed in a trans-
verse direction the water pipe must be Inst d within a larger pipe which size
shall be no less than six (6) inches ameter. Backfilling and Paving: The
permittee shall be required to p rly backfill the trench in such a manner as
to guarantee a well compact , stabilized sub -base prior to paving. The pave-
ment must be replaced, is original line, crown, and grade with an asphalt
mixture to confo 'th the surrounding road bed. The area of installation
must be k ooth for the traveling public at all times. The permittee will
be re ed at all times to take every precaution to protect the traveling
In regard to other utility installations, such as gas lines, telephone lines and
electric conduits, all the general specifications shall apply if they are to be
run under ground, with one exception: It would not be necessary to have these
lines within a larger pipe when crossing the right-of-way.
Dated this ..2 day of
Rec ended Appova /
Charles L. Plummer,
DESCHUTES COUNTY ROADMASTER
PERNI7TUI
Cx
C4,
It PACE551
2:
C.A
JYPIC-AL SECTION
DRAWFj of- PROPOSED
3�
o),57RIBUTMA/
Po!,I,rP
I NE A ND A 3 0
T. -r R 0 1) fi n C,4,8 L Z N D FS c
r_'lou,,y7-y ROAD R l U h T
OF
WAY IN SEC T.20 -S - R/0
'1/ hl
LrNUTIj c)F P, H
L. bY E 333