Loading...
11-566-Order Recorded 2/21/1968VOL 11 'AGE 566 IN THE COUNTY COURT OF THE STATE OF OREGON FOR THE COUNTY OF DESCHUTES Tri the Matter ) of ) ORDER Installation of water pipe line A permit is granted by Deschutes County to Kenneth J. Neel to install a 2" water line on or across Deschutes County right-of-way. A detailed description and map of this operation must be provided on the reverse side of this sheet. This permit is subject to the following gen- eral specifications and is revocable at any time upon written notice by the Deschutes County Court. GENERAL SPECIFICATIONS FOR PARTICULAR INSTALLATIONS Installing Pi e Line Parallel: All pipe lines running para lel with the road shall be in the existing ditch line, or no less than three (3) feet from the edge of the existing pavement edge. All pipe lines must be installed to a depth to be no less than two (2) feet and properly backfilled to the original grade line and with no obstructions to the drainage area. Permittee shall be responsible for any or all damages to the existing pavement, and shoulders or other objects or areas within the right-of-way. lat laid transversely to the road bed or right-of-way shall be installed in the fol 'ng manner: All pavement cuts prior to excavation shall be made with a breaking er so as to insure neat finish cut lines. All pipe lines shall be installed topth of no less than two 42) feet below the existing road- side ditch elevation. n all cases where a water linea is installed in a tran4-- verse direction the water a must be installed within a larger pipe which size shall be no less than six (6 ches in diameter. Backfilling and Paving: The permittee shall be required to pr ly backfill the trench insuch a manner as to guarantee a well compacted, stabile sub -base prior to paving. The pave- ment must be replaced to its original line, rown, and grade with an asphalt mixture to conform with the surrounding road b The area of installation must be kept smooth for the traveling public at al es. The permittee will be required at all times to take every precaution to p ct the traveling public. All signs and traffic controls shall be furnished the permittee. In regard to other utility installations, such as gas lines, teleph lines and electric conduits, all the general specifications shall apply if they o be run under ground, with one exception: It would not be necessary to have Men. cross ng the right-of-way* Dated this :2- day of,, 1960 Rec ended Approv,�l Charles L. Plummer, DESCHUTES COUNTY ROADMASTER VOL 11 MEW/ 17 �s 06 Fe e j_ )r0 /4 w ,, g 4 yCk Ile �3 r > ya ��' •`dt `� _x i-ol v /