HomeMy WebLinkAboutSurvey 20642CONNERS I CONDOMINIUM
LOCATED IN THE NW 1 /4 SW 1 /4 OF SECTION 26,
TOWNSHIP 17 SOUTH, RANGE 12 EAST, W.M.,
CITY OF BEND, DESCHUTES COUNTY, OREGON
SURVEYOR'S CERTIFICATE:__
I, DIRK P. DURYEE, A PROFESSIONAL LAND SURVEYOR IN THE STATE OF OREGON, DO
HEREBY CERTIFY THAT I OR THOSE UNDER MY DIRECT SUPERVISION, HAVE CORRECTLY
SURVEYED AND MARKED WITH LEGAL MONUMENTS THAT LAND REPRESENTED ON THIS
CONDOMINIUM PLAT OF "CONNERS I CONDOMINIUM" PLAT, SAID PLAT IS THE
NORTHWEST ONE —QUARTER OF THE SOUTHWEST ONE —QUARTER OF SECTION 26,
TOWNSHIP 17 SOUTH, RANGE 12 EAST, OF THE WILLAMETTE MERIDIAN, IN CITY OF
BEND, IN DESCHUTES COUNTY, OREGON, A PORTION OF PARCEL 3 OF PARTITION PLAT
2007-66 MORE PARTICULARLY DESCRIBED AS FOLLOWS:
BEGINNING AT THE INITIAL POINT, BEING A 5/8" REBAR WITH A BROKEN YELLOW
PLASTIC CAP AT THE SOUTHWEST CORNER OF ADJUSTED PARCEL 3 AS DESCRIBED IN
INSTRUMENT NUMBER 2018-27535 DESCHUTES COUNTY OFFICIAL RECORDS; SAID
INITIAL POINT BEARS SOUTH 89'59'40" WEST 121.34 FEET FROM A 5/8" REBAR WITH
YELLOW PLASTIC CAP MARKED 'TYE ENGINEERING" AT THE SOUTHEAST CORNER OF
PARCEL 3 PARTITION PLAT 2007-66; THENCE NORTH 00'06'38" WEST 358.91 FEET TO
A 5/8" REBAR; THENCE NORTH 89'52'53" EAST 245.93 FEET TO THE WEST RIGHT OF
WAY OF TUCSON WAY, TO LEAD AND TACK WITH NO WASHER; THENCE SOUTH
00'03'43" EAST 36.15 FEET ALONG THE WESTERN RIGHT OF WAY OF TUCSON WAY TO
A 5/8" REBAR WITH YELLOW PLASTIC CAP MARKED "TYE ENGINEERING"; THENCE
CONTINUING ALONG THE WESTERN RIGHT OF WAY OF TUCSON WAY 102.36 FEET
ALONG THE ARC OF A 150.00 FOOT RADIUS CURVE RIGHT, THE CHORD WHICH BEARS
SOUTH 19'2342" WEST 100.39 FEET TO A 5/8" REBAR WITH YELLOW PLASTIC CAP
MARKED "TYE ENGINEERING"; THENCE SOUTH 38'58'04" WEST 69.84 FEET TO A 5/8"
REBAR WITH YELLOW PLASTIC CAP MARKED "TYE ENGINEERING"; THENCE 143.01 FEET
ALONG THE ARC OF A 210.01 RADIUS CURVE LEFT, THE CHORD WHICH BEARS SOUTH
19'2717" WEST 140.26 FEET TO A 5/8" REBAR WITH YELLOW PLASTIC CAP MARKED
"TYE ENGINEERING"; THENCE SOUTH 00'0232" EAST 42.01 FEET TO A 5/8" REBAR WITH
YELLOW PLASTIC CAP MARKED `TYE ENGINEERING"; THENCE SOUTH 89'59'40" WEST
121.34 FEET ALONG THE NORTHERN RIGHT OF WAY OF CONNERS AVENUE TO THE
POINT OF BEGINNING.
CONTAINING 1.48 AC ACRES, MORE OR LESS.
'S NARRATIVE
WE WERE RETAINED BY CENTRAL OR REGIONAL HOUSING AUTHORITY, TO
PREPARE A CONDOMINIUM PLAT FOR THE BUILDING ON THE PARCEL OF LAND
DESCRIBED IN STATUTORY WARRANTY DEED RECORDED JULY 2, 2019 IN
INSTRUMENT NO. 2019-23079, DESCHUTES COUNTY OFFICIAL RECORDS.
LOCATED IN THE NW 1 /4 SW 1 /4 OF SECTION 26, TOWNSHIP 17 SOUTH,
RANGE 12 EAST, W.M., CITY OF BEND, DESCHUTES COUNTY, OREGON.
THE BOUNDARIES OF THIS PLAT WERE ESTABLISHED BY HOLDING MONUMENTS
FOUND PER SURVEYS OF RECORD (R1), (R2), AND (R3) AS SHOWN ON
SHEET 3 OF THIS PLAT.
BEARINGS OF THIS SURVEY ARE BASED ON THE CENTRAL OREGON
COORDINATE SYSTEM.
BASIS OF BEARINGS AND CONTROL FOR THIS SURVEY IS THE
CENTRAL OREGON COORDINATE SYSTEM (COCS). GPS
CALIBRATIONS WERE MADE FROM THE ORGN BASE STATIONS
(INCLUDING BNDM, REDM, LAPN, P387 SISTERS, PNVL, AND MDRS)
WITH TOPCON HIPER GPS. THE CALIBRATION TIES MULTIPLE COCS
POINTS USING PUBLISHED COORDINATES. THE COCS HORIZONTAL
DATUM IS NAD83 (91) AND USES A MOLONDENKSY
TRANSFORMATION. THE COCS VERTICAL DATUM IS NGVD 29
CITY OF BEND LAND USE # PLFP20210593
SHEET 1: SURVEYOR'S CERTIFICATE
DECLARATION
SURVEYOR'S NARRATIVE
DECLARATION SIGNATURES
SHEET 2: APPROVAL SIGNATURES
SHEET 3: BOUNDARY, BUILDING TIES, EASEMENTS
SHEET 4: PARKING AND LCE TIES
SHEET 5: FOUNDATION DIMENSIONS
SHEET 6-9: FLOOR LEVELS
SHEET 10: BUILDING SECTIONS
C U' COUM SURVEYOR
Az 0 L,
Deschutes County Official Records
Steve Dennison; County Clerk 202 1 -58678
01404360202100586-180010016
D-PLAT Cnt=1 Pgs=1 Stn=2 10/15/2021 03:44 PM
$50.00 $11.00 $61.00 $10.00 $6.00 $138.00
DECLARATION
KNOW ALL MEN BY THESE PRESENTS, THAT CONNERS I LIMITED PARTNERSHIP, AN
OREGON LIMITED PARTERSHIP, AS OWNERS OF A LEASEHOLD ESTATES IN THE LAND
HEREBY SUBDIVIDED HEREBY DECLARES THE MAP OF "CONNERS I CONDOMINIUM", AS
DESCRIBED IN THE ACCOMPANYING SURVEYOR'S CERTIFICATE, TO BE A TRUE AND
CORRECT PLAT THEREOF, AND HEREBY COMMITS SAID LAND TO THE OPERATION OF
THE OREGON CONDOMINIUM ACT AS LAID OUT IN CHAPTER 100 OF THE OREGON
REVISED STATUES.
THE PROPERTY AND IMPROVEMENTS DESCRIBED AND DEPICTED ON THE PLAT ARE
SUBJECT TO THE PROVISIONS OF O.R.S. 100.055 TO 100.627.
DECLARATION SIGNATURES
CONNERS I LIMITED PARTNERSHIP,
an Oregon limited partnership
By: Forbes Housing LLC,
an Oregon limited liability company
Its: General Partner
By: Central Oregon Regional Housing Authority,
a public body corporate and politic of the State of Oregon d/b/a Housing Works
Its: Manager
By:
Name: Geoff C. Wall
Title: Chief Financial Officer
STATE OF OREGON
COUNTY OF S u eS )
The foregoing instrument was acknowledged before me this day o6eViPM 2021, by
Geoff C. Wall, Chief Financial Officer of Central Oregon Regional Housing Authority, a public body
corporate and politic of the State of Oregon d/b/a Housing Works, the Manager of Forbes Housing
LLC, an Oregon limited liability company, the General Partner of Conners I Limited Partnershi , an
Oregon limited partnership.
N ry mmission Expires:Public for gon
y Co3+`5. 9949 5
Commission No.:
l5
0
RENEWS: 12/31 /21
jqV,r4)^ 15, Za255
CS 206412
2407—CONNERS I CONDOMINIUM SURVEY-4-21-2021.dwg
DESCHUTES COUNT SURVEYOR
FILED,DY:
CONNERS I CONDOMINIUM
LOCATED IN THE NW 1 /4 SW 1 /4 OF SECTION 26,
TOWNSHIP 17 SOUTH, RANGE 12 EAST, W.M.,
CITY OF BEND, DESCHUTES COUNTY, OREGON
CITY OF BEND LAND USE # PLFP20210593
el
��mwbglkf •
Y �REGON
May 12, 2010
DIRK P. DURYEE
65694PLS
RENEWS: 12/31 /21
APPROVALS
DES U S COUNTY SURVEYOR DATE
�7K/ / t/ 0 cr a.)
DESCHUT�UNTY CO ISSIONERS DATE
/0 - '76a 1
CITY eBEND ENGINEER DATE
CITY OF BEND P NING DIRECTOR DATE
SIGNATURE BY THE CITY OF BEND CONSTITUTES
ACCEPTANCE BY THE CITY OF ANY DEDICATION MADE
HEREON TO THE PUBLIC.
ASSESSOR'S CERTIFICATE:
HEREBY CERTIFY THAT ALL AD VALOREM TAXES,
ASSESSMENTS, FEES AND OTHER CHARGES REQUIRED BY LAW
TO BE PLACED ON THE 2021-2022 TAX ROLLS WHICH
BECAME A LIEN OR WILL BECOME A LIEN ON THIS PLAT
DURING THIS TAX YEAR, BUT NOT YET CERTIFIED TO THE TAX
COLLECTOR FOR COLLECTION, HAVE BEEN PAID TO ME:
DESCHUTES COUNTY ASSESSOR
-ZZ-Z f
DATE
CERTIFY THAT ALL TAXES HAVE BEET`� PAID AS OF THIS DATE:
DESCHUTES COUNTYCTAX COLLECTOR
-Al -,2o2 I
DATE
WATER RIGHTS STATEMENT:
THERE ARE NO WATER RIGHTS ASSOCIATED WITH THIS PROPERTY
Ln
cs 10 6 §2 --o
2407-CONNERS I CONDOMINIUM SURVEY_4-21-2021.dwg
CONNERS I CONDOMINIUM
LOCATED IN THE NW 1 /4 SW 1 /4 OF SECTION 26,
TOWNSHIP 17 SOUTH, RANGE 12 EAST, W.M.,
CITY OF BEND, DESCHUTES COUNTY, OREGON
CITY OF BEND LAND USE
i
I I I I I I
VILLAGE AT VILLAGE AT VILLAGE AT VILLAGE AT VILLAGE OAKTREE, PH.2 OAKTREEA PHAOAKTREE, PH.2 OAKTREE, PH.2 OAKTREE, PH.2 OAKTREE, PH.2 LOT 1 LOT
I LOT 5 I LOT 4 I LOT 3 I LOT 2 I I
I I I 17
N89-52'46"E 245.89'1 (R1) LEAD AND TACK,
NO WASHER
- - - - - - - _ N89'53'16"E (R2) _
- - - - - - - - - - - - - - - - - - - -
N89;5_f53 E 245. T -
60.73' 60.12' 125.08'
- - - - - - - - - - - - - - - -
#PLFP20210593
I
5/8" REBAR, 5/8" REBAR,
' YPC ILLEG. YPC ILLEG. oe��
5/8" REBAR WITH YPC
(ILLEGIBLE)co
5/8" REBAR. �
YPC "HWA" '
Imo' MONUMENT UNDER
ASPHALT,
�.0e SET 5/8" REBAR, C�
i B
�rn
co 00
PARTITION PLAT 2007-66 0 u')
PARCEL 2 �
M
_2 00
O
O p
LINE TABLE
LINE
LENGTH
DIRECTION
L1
101.03'
N36-55'12"W
L2
147.14'
N56'28'10"E
L3
57.92'
N73'44'58"E
L4
12.26'
S72'21'54"E
L5
25.59'
S53'52'51 "E
L6
62.39'
S75.05'24"W
Z 0
Z
SCALE: 1 "=40'
�-4--- 59.66'
I
CURVE TABLE
CURVE
LENGTH
RADIUS
TANGENT
CH BEARING
CH LENGTH
DELTA
C1
102.36'
150.00'
53.27'
S19'2342"W
100.39'
39.06'00"
C1(R1)
102.35'
150.00'
S19*2,V02"W
100.38'
39'05'48"
Cl (R2)
102.17'
150.00'
S19.28'09"W
100.21'
39'01'40"
Cl (R3)
102.35'
150.00'
N19'24'30"E
100.38'
39'05'48"
C2
143.01'
210.01'
74.40'
S19.27'17'W
140.26'
39'00'57"
C2(R1)
142.95'
210.01'
S1926'52"W
140.21'
3W00'08"
C2(R2)
143.20'
210.00'
S1926'54"W
140.44'
39'04'10"
142.95'
210.00'
S19.27.20"W
140.21'
1 39-00-08"
f
f
to
i
0
co
c p I
INITIAL POINT
5/8" REBAR,
YPC BROKEN
------ -- is
- - - - -- - - - - - - - -
S89.59'40"W 121.34'
S89.58'57"W 121.34' (R1)
. , "
YPC MARKED TYE ,
ENGINEERING"
AT EXACT
LOCATION. J
1
� � � Off• � � `2" �ji
ItK IV,
„�4�� oK
'4j •�L
S89 5915 W (R2) 5.0' PUE AND SIDEWALK
EASEMENT
NE CONNERS PER (R3)
AVE.(PUBUC)
SO.03'43"E
36.15'
N00'08'24"W
36.10' (R3)
S00.02'41 "E
36.44' (R2)
S00.08'52"E
36.13' (R1)
REBAR,
YPC "HWA%
DESTROYED DURING
CONSTRUCTION.
SET 5/8" REBAR,
YPC MARKED "TYE ENGINEERING"
AT EXACT LOCATION.
5/8" REBAR WITH YPC
MARKED: "HWA"
DESTROYED DURING
CONSTRUCTION.
SET 5/8" REBAR,
YPC MARKED "TYE ENGINEERING"
AT EXACT LOCATION.
5.0' PUE AND SIDEWALK EASEMENT
PER (R3)
5/8" REBAR,
YPC "HWA",
DESTROYED DURING
CONSTRUCTION.
SET 5/8" REBAR,
YPC MARKED "TYE ENGINEERING"
AT EXACT LOCATION.
SO'02'32"E 42.01'
S00.03'12"E 42.10' (R1)
SOO.05'11 "E 41.97' (R2)
NOO'02'44"W 42.10' (R3)
-LEAD AND TACK,
WASHER "HWA",
DESTROYED DURING
CONSTRUCTION.
SET 5/8" REBAR,
YPC MARKED "TYE
ENGINEERING"
AT EXACT LOCATION.
LEGEND
O SET 5/8" REBAR WITH YELLOW PLASTIC
CAP STAMPED "TYE ENGINEERING"
• FOUND MONUMENT AS NOTED
EX. PROPERTY LINE
ADJ. PROPERTY LINE
-------- EASEMENT LINE
GCE GENERAL COMMON ELEMENT
LCE LIMITED COMMON ELEMENT
OREFERENCE LOCATION
(R1) LL-17-0804, BY PATRICK GAGE COLE, PLS 79157,
FILED 8/7/2018, CS19708
(R2) PARTITION PLAT 2007-66, BY JAMES D. PERRY,
PLS 2407, FILED 11 /2/2007, CS17543
(R3) CARPENTER SUBDIVISION, BY DAVID R. WILLIAMS,
PLS 2686, FILED 8/18/1999, CS13736
1. THE ELEVATIONS SHOWN HEREON ARE BASED ON THE VERTICAL DATUM OF NGV29
AND WERE DERIVED FROM PUBLISHED CENTRAL OREGON COORDINATE SYSTEM
CONTROL POINT "GIS 008", ELEVATION= 3608.16
2. BUILDING WALLS SHOWN ARE AT RIGHT ANGLES AT THE CORNERS UNLESS NOTED
OTHERWISE. INTERIOR UNIT DIMENSIONS ARE TO THE INSIDE FACE OF UNFINISHED
WALL.
3. ANY AREAS NOT DESIGNED AS LIMITED COMMON ELEMENT OR AS PART OF A UNIT
ARE GENERAL COMMON ELEMENTS.
4. THIS PLAT IS SUBJECT TO THE "DECLARATION SUBMITTING CONNERS I
CONDOMINIUM TO CONDOMINIUM OWNERSHIP"
6. EASEMENT FOR INGRESS AND EGRESS ABOVE AND BELOW THE SURFACE OF
THE LAND AS IMPLIED BY RESERVATION OF MINERAL RIGHTS IN THE ABOVE
INSTRUMENT. COVERING ALL 40 ACRES OF THE NW 1 /4 OF THE SW 1 /4 OF
SECTION 26, TOWNSHIP 17 SOUTH ,RANGE 12 EAST, VOL 65, PAGE 527,
RECORDED OCTOBER 25, 1944
5. BASIS OF BEARINGS AND CONTROL FOR THIS SURVEY IS THE CENTRAL OREGON
COORDINATE SYSTEM (COCS). GPS CALIBRATIONS WERE MADE FROM THE ORGN
BASE STATIONS (INCLUDING BNDM, REDM, LAPN, P387 SISTERS, PNVL, AND MDRS)
WITH TOPCON HIPER GPS. THE CALIBRATION TIES MULTIPLE COCS POINTS USING
PUBLISHED COORDINATES. THE COCS HORIZONTAL DATUM IS NAD83 (91) AND
USES A MOLODENKSY TRANSFORMATION. THE COCS VERTICAL DATUM IS NGVD
29
DESCHUTES -`` ••� •
• ' /
� • �
2010
DIRK P. DURYEE
65694PLS
RENEWS: 12/31 /21
CS 2os42
I CONDOMINIUM SURVEY_4-21-2021.dwg
3'
CONNERS I CONDOMINIUM
LOCATED IN THE NW 1 /4 SW 1 /4 OF SECTION 26,
TOWNSHIP 17 SOUTH, RANGE 12 EAST, W.M.,
CITY OF BEND, DESCHUTES COUNTY, OREGON
CITY OF BEND LAND USE # PLFP20210593
9'x20' TYPICAL PARKING
LCE PARKING DIMENSION
.....___ .-TED
60.12'
12.5
N68'14'52"W 14.92' P1 P2 P3 P4 P5 P6 P7 P8 P9 P1 P11 'n
SO'00'00"E 20.00' 9'
I
S55011'31 "E 42.04' \ N90'00'00"E 99.00'
S80027'33"W 3.02'
SO'00'00"E 20.00'
S78'14'48"W 17.42'
00 00 W 81.009'9P23 P2�N!�U
P26 P27 P28 P29 P30 P31
`TRASH ENCLOSURE —GCE
I
125.08'
P12 P13 Pi P15 P16 P17 P18 Pi P20 P21 I P22 S69'22'40"W 17.14'
SO'00'00"E 20.00'
A: A:
N90'00'00"E 99.03'
•N77'54'50"W 2.41'
•N90'00'00"W 10.91' S47'56'17"W 35.82'
9 9 I '
P32 P33 P34 P35 P36 P37 P38
' SO'00'00"E 20.00'
NO'00'00"E 20.00'—J
P51 9 I P39 P40 P41 P42 P43 P44
S0006'38"E 45.00'— I P52
91
N90'00'00"W 9.00' /
P53 t--N3'47'24"W 44.10' SO'00'00"E 20.00'
P54
P55 .-N90'00'00"E 63.00=. N2'23'09"W 24.02'
NO'06'38"W 9.00'
I P45 P46 P47 P48 P49 P50
I P56
P57 /
p P5800
P59 �0�1
W P60
to P61 EXTERIOR FACE ww11
�v
o OF FOUNDATION
o P62 SEE SHEET 5
cn FOR DIMENSIONS /
P63 9
SCALE: 1 " 40' /
20
SO'06'38"E 18.00' I 20'
w� P64 g'
p P65
M
O P66 /
W P67
0 /
M P68
t0
I O O P69 '
N
LEGEND
GCE GENERAL COMMON ELEMENT
LCE LIMITED COMMON ELEMENT
P# LCE PARKING
NOTES
1. THE ELEVATIONS SHOWN HEREON ARE BASED ON THE VERTICAL DATUM
OF NGV29 AND WERE DERIVED FROM PUBLISHED CENTRAL OREGON
COORDINATE SYSTEM CONTROL POINT "GIS 008", ELEVATION= 3608.16
2. BUILDING WALLS SHOWN ARE AT RIGHT ANGLES AT THE CORNERS
UNLESS NOTED OTHERWISE. INTERIOR UNIT DIMENSIONS ARE TO THE
INSIDE FACE OF UNFINISHED WALL.
3. ALL UNIT MEASUREMENTS MAY VARY +/— 0.05 FEET. UNIT DIMENSIONS
SHOWN HEREON ARE SHOWN THE THE NEAREST 0.01 FOOT FOR CLOSURE
PURPOSES.
4. ANY AREAS NOT DESIGNED AS LIMITED COMMON ELEMENT OR AS PART
OF A UNIT ARE GENERAL COMMON ELEMENTS.
5. THIS PLAT IS SUBJECT TO THE "DECLARATION SUBMITTING CONNERS I
CONDOMINIUM TO CONDOMINIUM OWNERSHIP"
� P7o g'
N0006'38"W 9.00' I
20 I ESC °DES COUNTY, SURVEYOR
P71 g' Qom►` .
P72 FILED ZU ZOZ B ■ i
SO'06'38"E 45.00' P73
P74
P75 9
S63'03'36"W 34.94'
— — — — — — — — — — — — — — — — — —
NE CONNERS
AVE.(PUBUC)
PARKING
SCALE: 1" = 40'
RENEWS: 12/31 /21
�tl
zosa2-
2407—CONNERS I CONDOMINIUM SURVEY_4-21-2021.dwg
0.6
0.7(
0.7
0.7
0.1
1.
0.1
0.7�
2.93'
2.93'
SCALE: 1 "= 20'
Ha;]
0.84
1.50
0.84'
0.89
• e
0."
1.
0.�
A
HE
CONNERS I CONDOMINIUM
LOCATED IN THE NW 1 /4 SW 1 /4 OF SECTION 26,
TOWNSHIP 17 SOUTH, RANGE 12 EAST, W.M.,
CITY OF BEND, DESCH U TES COUNTY, OREGON
)F BEND LAND USE # PLFP20210593
0.67'
LEGN D
GCE GENERAL COMMON ELEMENT
LCE LIMITED COMMON ELEMENT
NOTES
1. THE ELEVATIONS SHOWN HEREON ARE BASED ON THE VERTICAL DATUM
OF NGV29 AND WERE DERIVED FROM PUBLISHED CENTRAL OREGON
COORDINATE SYSTEM CONTROL POINT "GIS 008", ELEVATION= 3608.16
2. BUILDING WALLS SHOWN ARE AT RIGHT ANGLES AT THE CORNERS
UNLESS NOTED OTHERWISE. INTERIOR UNIT DIMENSIONS ARE TO THE
INSIDE FACE OF UNFINISHED WALL.
3. ALL UNIT MEASUREMENTS MAY VARY +/— 0.05 FEET. UNIT DIMENSIONS
SHOWN HEREON ARE SHOWN THE THE NEAREST 0.01 FOOT FOR CLOSURE
PURPOSES.
4. ANY AREAS NOT DESIGNED AS LIMITED COMMON ELEMENT OR AS PART
OF A UNIT ARE GENERAL COMMON ELEMENTS.
5. THIS PLAT IS SUBJECT TO THE "DECLARATION SUBMITTING CONNERS I
CONDOMINIUM TO CONDOMINIUM OWNERSHIP"
RENEWS: 12/31 /21
"MAI, 1osa2-
2407—CONNERS I CONDOMINIUM SURVEY_4-21-2021.dwg
A D),
B
0.92'
5 44 10.46' 24.60' I9 0.95'I 11.36'
0.95 0 95' 1 I 1
I I �_
0.65' I I I n
rl
C; ---- u'-------- I --- 1---I - N ------ C;
0-0.84'
1.51' O
Lo 0.84' 1.07'-w
0.95' I I I o
0.' I 1 11.07' '-
68
GCE STRUCTURAL COLUMN (TYP.) M 0.69' I I I
I
o0
_
0.70'
1
1
1.47'
I O
1 1
0.70'
�
0.98'
I 100
UNIT 2
UNIT 2
I
25.664
STAIRS
ELEVATOR
206 S.F.
h-v)
N
67 S.F. I
. s.so'M
�, 17.68
(69.600 co
'
73�
I co
I
I
9.60' '- 17.68'
r- 29.39'
52
00'
O 'o
14.02' N
( 18.94'
3.63'
rC'4O.68'
0.71
( 4.69'
1
.01'
1
1 s.23'
UNIT 2 00
0.66 ,
1
16.23' 1
1,688 S.F. N
N
1
I 1
FFE 3558.00
- 0.70;
I
I N 04
M
SCALE: 1 "=20'
GCE STRUCTURAL COLUMN (TYP.)
1.53 O Lo 7 02'
0 0.70' ( I N N
,� IL 1I i o
co
0.71' UNIT 1-FIRST LEVEL j1 26.08' 06
1.04' 13,194 S.F. 1 8.65'
1.10FFE 3557,00 I
I I I N a
I 0.91
a
1.50' I O I
C-4 0.91 I I 0.74
2.84' I I I
LL I I °;
I I
N I I I N
I I 0.92'
Q, 2.84' I l I
�
-0.90' I I 16.21'
w
W
yp
V
N
i IM
I I
I I
I I
c0.80' I I
°' I I
-0.90' O 1
lt1. 2
0.44' 1
I U-i
1 0.65'
N i 0.84'I
0.84
co
0.501 0.96' *--
1.48' O I I I
0.25'
0o I I've I
I IN I
STAIRS -GCE
N0.78' I 225 S.F.
o I 11.s9 I
- 0.87' ( N I
1.50' O i cq I cq I
0.87 11.13' ��I �' III
RENEWS: 12/31 /21
o to1.0011.69'
5.00' 1COUNTY SURVEYOR
0 10.30' j
g0 90'-0.91'19 45'0 0.80' 1 FILE Io 2! 2O BY: - TITLE: CONNERS I CONDOMINIUM
4.65' 0.83' "aw
CONNERS I CONDOMINIUM
LOCATED IN THE NW 1 /4 SW 1 /4 OF SECTION 26,
TOWNSHIP 17 SOUTH, RANGE 12 EAST, W.M.,
CITY OF BEND, DESCHUTES COUNTY, OREGON
CITY OF BEND LAND USE # PLFP20210593
LEGEND
GCE GENERAL COMMON ELEMENT
LCE LIMITED COMMON ELEMENT
NOT S
1. THE ELEVATIONS SHOWN HEREON ARE BASED ON THE VERTICAL DATUM
OF NGV29 AND WERE DERIVED FROM PUBLISHED CENTRAL OREGON
COORDINATE SYSTEM CONTROL POINT "GIS 008", ELEVATION= 3608.16
2. BUILDING WALLS SHOWN ARE AT RIGHT ANGLES AT THE CORNERS
UNLESS NOTED OTHERWISE. INTERIOR UNIT DIMENSIONS ARE TO THE
INSIDE FACE OF UNFINISHED WALL.
3. ALL UNIT MEASUREMENTS MAY VARY +/- 0.05 FEET. UNIT DIMENSIONS
SHOWN HEREON ARE SHOWN THE THE NEAREST 0.01 FOOT FOR CLOSURE
PURPOSES.
4. ANY AREAS NOT DESIGNED AS LIMITED COMMON ELEMENT OR AS PART
OF A UNIT ARE GENERAL COMMON ELEMENTS.
5. THIS PLAT IS SUBJECT TO THE "DECLARATION SUBMITTING CONNERS I
CONDOMINIUM TO CONDOMINIUM OWNERSHIP"
n.
FIRE RISER -UNIT 1
55 S.F.
IboC W.
FIRST FLOOR
SCALE: 1" = 20'
� 2osa2-
2407-CONNERS I CONDOMINIUM SURVEY_4-21-2021.dwg
A D B
UNIT 2 DECK
65 S.F.
UNIT 2 DECK 5.75' I 110.66'
65 S.F. d 35.55' M rn c� i00
.7512.14'
L 0 1 Lo Lo10. 6' ' L6
`- I 110.86' I
5.83' I I I
I I I N
g - - - - g
I I I M
N I I
GCE
I MECHANICAL
I I CHASE
UNIT 2 DECK 5.83' I I I 5.83'
65 S.F. •83 I 1 I 6 09 UNIT 2 DECK
00 ao M I ( I 00 00 00 65 S.F.
I I I ``'• o 0
0.85' .8 5.64' 1 7.12' 1 { o 5.83'
°r a0 I I I
0
11.38' 1 9.42
UNIT 2 DECK •83 I 7.12' \29.19' �-3.10'
65 S.F. 5.83' I04
I tto I oI 17.81' o
"'•I `�?106 23.02'
4 UNIT 2 ELEVATORI 00 �1 17.81 21.94'
UNIT 2 DECK
65 S.F.
0.85'
UNIT 2 DECK
65 S.F.
SCALE: 1 "=20'
N 67 S.F1 9.42' 19.65' (.0
1 9.92' I I r
5.83' 1 I I
4 I ( 26.12'
00
0,° r� UNIT 2 STAIRS I I
205 S.F. I
5.73' I I
'00.$ 5.73' I
o 11.28' I I I I
8 UNIT 2-2ND LEVEL -------,I
5.93' 13 797 S.F. I
00
Lo
N
5.93'
0o ' eco -co
00 o0 0
o a
UNIT 2 DECK
65 S.F. 5.93'
N
0)
CV
UNIT 2 DECK �r- 5.93'
65 S.F. - .83
0 00
N
0.85' •8 5.64'
•�� 5.64'
00
0 0 11.38
UNIT 2 DECK--*"-"15831
65 S.F. F-5.83'
M
N
00
(EXCLUDES DECKS, °i
STAIRS, ELEVATORS,
ROOF DECKING, AND
ELECTRIC)
I I I
I I I
I I I
I 1 I 5.83'
I
I { { o
i I �
10.17�'
I
I I
I I I
i
I I I
I i
I I GCE
I I I MECHANICAL
I ( CHASE
I I
I 5.50' I UNIT 2
5.00' ELECTRIC
i d ( 125 S.F.
1 6.58' 1 M
to
N
(6
21.94'
CONNERS I CONDOMINIUM
LOCATED IN THE NW 1 /4 SW 1 /4 OF SECTION 26,
TOWNSHIP 17 SOUTH, RANGE 12 EAST, W.M.,
CITY OF BEND, DESCHUTES COUNTY, OREGON
CITY OF BEND LAND USE # PLFP20210593
UNIT 2 LEGEND -
ROOF
DECK
317 S.F. GCE GENERAL COMMON ELEMENT
LCE LIMITED COMMON ELEMENT
NOTES
1. THE ELEVATIONS SHOWN HEREON ARE BASED ON THE VERTICAL DATUM
OF NGV29 AND WERE DERIVED FROM PUBLISHED CENTRAL OREGON
COORDINATE SYSTEM CONTROL POINT "GIS 008", ELEVATION= 3608.16
2. BUILDING WALLS SHOWN ARE AT RIGHT ANGLES AT THE CORNERS
UNLESS NOTED OTHERWISE. INTERIOR UNIT DIMENSIONS ARE TO THE
INSIDE FACE OF UNFINISHED WALL.
3. ALL UNIT MEASUREMENTS MAY VARY +/- 0.05 FEET. UNIT DIMENSIONS
SHOWN HEREON ARE SHOWN THE THE NEAREST 0.01 FOOT FOR CLOSURE
PURPOSES.
4. ANY AREAS NOT DESIGNED AS LIMITED COMMON ELEMENT OR AS PART
OF A UNIT ARE GENERAL COMMON ELEMENTS.
5. THIS PLAT IS SUBJECT TO THE "DECLARATION SUBMITTING CONNERS I
CONDOMINIUM TO CONDOMINIUM OWNERSHIP"
UNIT 2 DECK 5 83' ooI M I
65 S.F.
�I 121 .08' II
I ED00 PRO I NAL
.8 5.64' S
0.85' 5.$5.64' 1 1 I AU EYOR
o I I I000 11.38' 1 1 1
•83UNIT 2 DECK OREGON
65 S.F. 5.83 11.93 My1,2010I i
I I 1 UNIT 2 STAIRS DIRK6569 DURYEE
°' 232 S.F.
/c", RENEWS: 12/31 /21
0�21' 0 1 " I SECOND FLOOR
I 0.76' SCALE: 1" = 20'
5.83' I 11.82'
•70) o I o) 16.77' I TITLE: CONNERS I CONDOMINIUM
to
N 35.89' I I I COSURVEYOR
UNIT 2 DECK .75 65 S.F. I I JOB N0: 2407
IL EE-iilV/Zo ZU Bylaw SCALE: 1 "=20' BY: ATT
A D B _ 7-19-2021
SHEET: 7 OF 10 725 NW HILL, BEND, OR
97703 541-389-6959
2407-CONNERS I CONDOMINIUM SURVEY-4-21-2021.dwg
CS 2os42-
SCALE: 1 "= 20'
A D B
UNIT 2 DECK
65 S.F.
1 6.19'L1O.45' 12.14'
UNIT 2 DECK
'75 0 35.55'
65 S.F. i� woo
O I 00 110.45
10.86' 1LI 6.19'
.75
5.83' I
I I I N
B----------.--- 7---I---- ,.---- B
in
N I I
GCE
MECHANICAL
UNIT 2 DECKM 5.83' 2
I CHASE 5.835
i.h9
' UNIT 2 DECK
65 S.F. •75 65 S.F.00 w 00 o 0
7 5.64'
0.85' 5.64' I I I 5.99'
75 .
00 M UNIT 2 ELEVATOR 00
70 S.F.
UNIT 2 DECK 75 I IF2'9.19' 3.10'
65 S.F. 0.67'
5.83' 32.7�17.98' 8
o
9.9V_i177.63' 00
7.1' .98' N
N 9.188 119.65'
5.00'
UNIT 2 DECK 5.83' I I I UNIT 2 STAIRS
.83 I I I 210 S.F.
65 S.F.
"o co
co 3.10'
0.85' 83
5.74'
0c0N•I I I
UNIT 2 DECK UNIT 2-3RD LEVEL
65 S.F. 13,741 S.F. I i 00
UNIT 2 DECK
65 S.F.
0o
N
5.93'
.
000 i
000
0 r-
(EXCLUDES DECKS,
STAIRS,
ELEVATORS, AND
ELECTRIC)
-5.93'
rn
(V
/-5.93'
UNIT 2 DECK
65 S.F. ''
00
O
0.85'
00
17
-
UNIT 2 DECK
65 S.F.
5.83'-�
UNIT 2 DECK
65 S.F. -
0.85'-�
UNIT 2 DECK
65 S.F.
UNIT 2 DECK
65 S.F.
00 O N
5.64'
7 5.64'
00 0o
M
M GCE
N MECHANICAL
CHASE
5.8-00 3 11.38'
ao 00
r r
� r
0)
M
4
N
5.83'
5.64'
5.64'
-11.38'
5.83'
35.89'
A
5.00'-\ 5.50
0 E581'
06
12.08'
I
11.95'
0 I co
rn
I
5.83'
0
O
N
10.17'
Lo
UNIT 2 ELECTRIC
125 S.F.
�I
MI
rn
I
UNIT 2 STAIRS
235 S.F.
I
11.95' 1
6.77'
rn
THIRD FLOOR
SCALE: 1" = 20'
CONNERS I CONDOMINIUM
LOCATED IN THE NW 1/4 SW 1/4 OF SECTION 26,
TOWNSHIP 17 SOUTH, RANGE 12 EAST, W.M.,
CITY OF BEND, DESCHUTES COUNTY, OREGON
CITY OF BEND LAND USE # PLFP20210593
LEGEND
GCE GENERAL COMMON ELEMENT
LCE LIMITED COMMON ELEMENT
NOTES
1. THE ELEVATIONS SHOWN HEREON ARE BASED ON THE VERTICAL DATUM
OF NGV29 AND WERE DERIVED FROM PUBLISHED CENTRAL OREGON
COORDINATE SYSTEM CONTROL POINT "CIS 008", ELEVATION= 3608.16
2. BUILDING WALLS SHOWN ARE AT RIGHT ANGLES AT THE CORNERS
UNLESS NOTED OTHERWISE. INTERIOR UNIT DIMENSIONS ARE TO THE
INSIDE FACE OF UNFINISHED WALL.
3. ALL UNIT MEASUREMENTS MAY VARY +/- 0.05 FEET. UNIT DIMENSIONS
SHOWN HEREON ARE SHOWN THE THE NEAREST 0.01 FOOT FOR CLOSURE
PURPOSES.
4. ANY AREAS NOT DESIGNED AS LIMITED COMMON ELEMENT OR AS PART
OF A UNIT ARE GENERAL COMMON ELEMENTS.
5. THIS PLAT IS SUBJECT TO THE "DECLARATION SUBMITTING CONNERS I
CONDOMINIUM TO CONDOMINIUM OWNERSHIP"
RENEWS: 12/31 /21
2407-CONNERS I CONDOMINIUM SURVEY-4-21-2021.dwg
SCALE: 1 "=20'
UNIT 2 DECK
65 S.F.
A( B
UNIT 2 DECK
65 S.F.-�
00
5.75'=
5.75
00
UNIT 2 DECK--"''
65 S.F.
UNIT 2 DECK
65 S.F.
5.83'
0.85'--
5.83'
co
0
UNIT 2 DECK----'
65 S.F.
00
00
0
Ir-
UNIT 2 DECK
65 S.F.
UNIT 2 DECK
65 S.F.
A D B
UNIT 2 DECK
5.75' I 6.19' 10.45' 65 S.F.
b 35.55' I aMo 110.45' ono. 12.14'
0 1 0
_ 10.86 6.19'
5.75' I I
5.83' I I I cq
---------I----7---- - - - B
po
MECHANICAL
I I CHAFE
5.83'
5.83'
I I 5�99, UNIT 2 DECK
po I ( 0 0 65 S.F.
I 11.28'
5.64 1 I 5.99'
5.64' 1 7.12' I 5.83' .
_ ( I00
F9.88,°°
5.75' 0.67'29.19'
2.73' 17.98'
7.63' � ��
UNIT 2 ELEVATOR I 117.98co
70 S.F.1 9.88' 1 19.65N
9•92' I I
5.83' 1 5.00'co
1
I
•
5.73'
5.74' I I
o -co I I
5.83' 1 1 I
5.93'
UNIT 2-4TH LEVEL
^00Lo 13, 458 S.F. Li
A
(EXCLUDES DECKS,
STAIRS, ELEVATORS,
5.93' AND ELECTRIC)
5.83'
�
-co
ci I I
5.83'
5.93'
04 I
I I
5.93' I
o �i 5.83'
o,
5.75' 5.64'
0.85' 5.64'
5.75'- ao � 00
O O M
�5.75'
UNIT 2 DECK
65 S.F. 5.83'
10.17'
I
I
I
I
I
5.83' I
3.10'
/-UNIT 2 STAIRS
210 S.F.
3.10'
GCE 5.50' UNIT 2 ELECTRIC
MECHANICAL I I
CHASE 15.00' 1125 S.F.
�. 6.58'
o
1 00
100 I 12.08' , I
5.64' I 1 O)
5.64'
00 N
5.83'
5.83'
12.03' I UNIT 2 STAIRS
M I I 1230 S.F.
o
I I
5.83' I 12.03'
5.00' 4.69' IL
I L 12.54'
UNIT 2 DECK 30.01, 1 1 1
345 S.F.
A D B
UNIT 2 DECK--
,,,,
S.F. �
5.83'�
0.85'
5.83--
00
UNIT 2 DECK---'
65 S.F.
v�
M
N
5.83'
FOURTH FLOOR
SCALE: 1" = 20'
CONNERS I CONDOMINIUM
LOCATED IN THE NW 1 /4 SW 1 /4 OF SECTION 26,
TOWNSHIP 17 SOUTH, RANGE 12 EAST, W.M.,
CITY OF BEND, DESCHUTES COUNTY, OREGON
CITY OF BEND LAND USE # PLFP20210593
i
IL•` 1
1 • • : ,l 474 i
LEGEND
GCE GENERAL COMMON ELEMENT
LCE LIMITED COMMON ELEMENT
NOTES
1. THE ELEVATIONS SHOWN HEREON ARE BASED ON THE VERTICAL DATUM
OF NGV29 AND WERE DERIVED FROM PUBLISHED CENTRAL OREGON
COORDINATE SYSTEM CONTROL POINT "GIS 008", ELEVATION= 3608.16
2. BUILDING WALLS SHOWN ARE AT RIGHT ANGLES AT THE CORNERS
UNLESS NOTED OTHERWISE. INTERIOR UNIT DIMENSIONS ARE TO THE
INSIDE FACE OF UNFINISHED WALL.
3. ALL UNIT MEASUREMENTS MAY VARY +/- 0.05 FEET. UNIT DIMENSIONS
SHOWN HEREON ARE SHOWN THE THE NEAREST 0.01 FOOT FOR CLOSURE
PURPOSES.
4. ANY AREAS NOT DESIGNED AS LIMITED COMMON ELEMENT OR AS PART
OF A UNIT ARE GENERAL COMMON ELEMENTS.
5. THIS PLAT IS SUBJECT TO THE "DECLARATION SUBMITTING CONNERS I
CONDOMINIUM TO CONDOMINIUM OWNERSHIP"
RENEWS: 12/31 /21
2407-CONNERS I CONDOMINIUM SURVEY_4-21-2021.dwg
GCE
EXTERIOR FACE OF BUILDING
0
0
c
r
GCE
UNIT 2
83.03'
UNIT 2
83.03'
UNIT 2
83.03'
UNIT 1
81.98'
EXTERIOR FACE OF BUILDING
LEGEND
GCE GENERAL COMMON ELEMENT
LCE LIMITED COMMON ELEMENT
CONNERS I CONDOMINIUM
LOCATED IN THE NW 1 /4 SW 1 /4 OF SECTION 26,
TOWNSHIP 17 SOUTH RANGE 12 EAST, W.M.,
CITY OF BEND, DESCHUTES COUNTY, OREGON
CITY OF BEND LAND USE # PLFP20210593
lo UNIT 2
o6 59.16'
0 UNIT 2
M 06 59.16'
STAIRS 8 UNIT 2
UNIT 2 00 59.16'
0
UNIT 0 UNIT 1
2 4
r
11.54� 58.05'
SECTION B-8
SCALE: I" = 20'
STAIRS—
4 LEVEL
UNIT 2
uri Lo
ul
Lco�2—
o
ao
rc(cRol
FFE FINISH FLOOR ELEVATION STAIRS— 0
LEVEL 1
GCE
NOTES 20.32'
1. THE ELEVATIONS SHOWN HEREON ARE BASED ON THE VERTICAL DATUM
OF NGV29 AND WERE DERIVED FROM PUBLISHED CENTRAL OREGON
COORDINATE SYSTEM CONTROL POINT "CIS 008", ELEVATION- 3608.16
2. BUILDING WALLS SHOWN ARE AT RIGHT ANGLES AT THE CORNERS
UNLESS NOTED OTHERWISE. INTERIOR UNIT DIMENSIONS ARE TO THE
INSIDE FACE OF UNFINISHED WALL.
3. ALL UNIT MEASUREMENTS MAY VARY +/— 0.05 FEET. UNIT DIMENSIONS
SHOWN HEREON ARE SHOWN THE THE NEAREST 0.01 FOOT FOR CLOSURE
PURPOSES.
4. ANY AREAS NOT DESIGNED AS LIMITED COMMON ELEMENT OR AS PART
OF A UNIT ARE GENERAL COMMON ELEMENTS.
5. THIS PLAT IS SUBJECT TO THE "DECLARATION SUBMITTING CONNERS I
CONDOMINIUM TO CONDOMINIUM OWNERSHIP"
GCE
40 PC?
LEVEL4
PFE: 3592.375
LEVEL 3
FFE: 3582.1
LEVEL _2�
FFE:3572.00�
LEVEL t
FFE:3557.0�
EXTERIOR FACE OF BUILDING
_ LEVEL4--
0
cd
L�63.032
_ LE_VE_L 4
FFE: 3592.375�
FFE: 3592W5
o
UNIT 2
_ LEVEL�3_
06
63.03'
_ LEVEL
FFE: 3582.18
FFE: 3582.18
$
UNIT 2
LEVEL_2
ad
63.03'
_ LEVEL_2
NO
FFE:3572.00 EXTERIOR FACE OF BUILDING
FFE:35
0
LEVEL 1
UNIT 1
1
35 FFE:57.00
_
62.03'
LEVEL
_ FFE.3557 00 '--W
SECTION C— C
SCALE: 1 " = 20'
UNIT 2
UNIT
2
�
�
UNIT
2
DECK
163.41'
Z
.
5394'
S83'
.— LEVEL 4
FFE: 3592.375 v
UNIT 2
163.41'
UNIT
2
w
rn Q
�
_
UNIT
2
53.94'
5.64' DECK LEVEL 3
FFE: 3582.18 v
2
163.41
UNIT
2
w
w
a00d
UNIT
2
53.94
DECK
5.64 _ LEVEL 2
FFE:3572.00
UNIT
1
UNIT
0
UNIT
1
2
r
163.41'
6.91'
1
58.83'
_ LEVEL 1_�
FFE:3557.00 v
4X4ILoI�����
DESCHUTES COUNTY SURVEYOW
lot B L
B�
RENEWS: 12/31 /21
w
cs 14642 -
2407—CONNERS I CONDOMINIUM SURVEY_4-21-2021.dwg